4<br />

5<br />

140 Modeling with Circuit Components<br />

Flag Drain-Source-Over voltage FAULT_VDS real<br />

Flag Gate-Source-Over voltage FAULT_VGS real<br />

Flag Over current FAULT_I real<br />

Flag Over temperature FAULT_TEMP real<br />

Component Nodes<br />

Description Node Name Nature<br />

GATE GATE electrical<br />

SOURCE SOURCE electrical<br />

DRAIN DRAIN electrical<br />

BULK BULK electrical<br />

Dynamic BJT Model<br />

>>Basics>Circuit>Semiconductors Device Level<br />

The BJT model is a modular model with definable simulation levels. Different simulation<br />

depths can be selected for the electrical and thermal behavior of the model.<br />

You can define two simulation levels for the electrical and three simulation levels for the thermal<br />

behavior. Each level combination has a certain set of parameters. The values of them can<br />

be defined in the model dialog. The component outputs are true of all types of the BJT models.<br />

They are listed at the end of the model description. See also “Thermal Semiconductor Model”<br />

on page 126 and “Temperature, Voltage, and Current Dependencies” on page 125..<br />

Dialog Settings<br />

� «Electrical Behavior Level»<br />

In the list, select the Electrical Behavior Level —0, or 1.<br />

� «Electrical Parameters»<br />

Define the electrical BJT parameters according to the selected electrical behavior level. Look<br />

their meaning up in the parameter table below. Common parameter types. Enter a numerical<br />

value, a variable, or an expression in the text box.<br />

� «Thermal Behavior Level»<br />

In the list, select the Thermal Behavior Level —0,1, or 2.<br />

� «Thermal Parameters»<br />

Define the thermal BJT parameters according to the selected thermal behavior level. Look<br />

their meaning up in the parameter table below. Common parameter types. Enter a numerical<br />

value, a variable, or an expression in the text box.<br />

«Freewheeling Diode»<br />

Define the freewheeling diode parameters. They are effective for all behavior levels. Look<br />

their meaning up in the parameter table below. Common parameter types. Enter a numerical<br />

value, a variable, or an expression in the text box.