<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 273<br />

«Scanning Frequency [Hz]»<br />

The scanning frequency corresponds to 1/TS of the FFT model parameter. The value should<br />

be at least twice greater than the highest analyze frequency. Enter a numerical value in the<br />

text box or use the pin to connect a quantity. Please note: The scanning frequency must be a<br />

positive value.<br />

� � «Use Pin»<br />

If the box is checked, the sample time is defined by the quantity connected to the pin, otherwise<br />

the value in the text box is used.<br />

Component Parameters<br />

Description [Unit] Parameter Name Data Type<br />

Input Signal INPUT real<br />

Cut-off Frequency [Hz] TS real<br />

Delay [s] TDELAY real<br />

Period TPERIO real<br />

FFT-type TYPE real<br />

Window Type WINDOW real<br />

Cut-off Frequency [Hz] FCUT real<br />

Amplitude filter AMPLFLT real<br />

Component Outputs<br />

Description [Unit] Parameter Name Data Type<br />

0. … 23. Harmonic wave AMPL[n] real<br />

Direct Component AMPL[0] real<br />

0. … 23. Phase Angle in Radians [rad] PHI[n] real<br />

0. … 23. Phase Angle in Degrees [deg] PHIDEG[n] real<br />

0. … 23. Frequency in Hz FREQ[n] real<br />

Fundamental Frequency [Hz] FREQ[1] real