Using Simulation Parameters<br />

<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 53<br />

The following table lists the simulation parameters, which control the simulation, and how to<br />

access them. All simulation parameter names are case insensitive, but the qualifier SECM is<br />

case sensitive.To display, for example, the current time step you have to define an expression<br />

var1:=h and define var1 as output.<br />

System T, t Current simulation time in seconds.<br />

constants H, h<br />

(read only)<br />

PI<br />

Current simulation time step in seconds.<br />

System variable. π = 3.141592654<br />

General<br />

simulationparameters<br />

(read/<br />

write)<br />

Circuit<br />

simulator<br />

(read/<br />

write)<br />

SML Text in the Schematic<br />

TRUE Logic operator. Provides the value '1'.<br />

FALSE Logic operator. Provides the value '0'.<br />

SECM.ITERAT Current number of iterations.<br />

TEND Simulation end time in seconds (TR).<br />

HMIN Minimum time step in seconds (TR).<br />

HMAX Maximum time step in seconds (TR).<br />

THETA Global ambient temperature for temperature dependent<br />

components (TR, AC, DC).<br />

FSTART Start frequency of simulation in Hz (AC).<br />

FEND End frequency of simulation in Hz (AC).<br />

FSTEP Frequency step time of simulation in Hz (AC).<br />

ACSWEEPTYPE Sweep type. 0=linear, 1=decadic (AC).<br />

EMAX Maximum error in A (AC, DC).<br />

ITERATMAX Maximum number of iterations (DC).<br />

RELAXMAX Maximum number of relaxation (DC).<br />

SECM.SOLVER Used integration method. 0=Euler, 1=Trapez<br />

SECM.LDF Local discretization error.<br />

SECM.ITERATMAX Maximum number of iterations for one simulation step.<br />

SECM.IEMAX Maximum current sum error.<br />

SECM.VEMAX Maximum voltage error.<br />

Edit window to create a SML header<br />

In the «SML-Header» dialog, statements<br />

in SML notation can be entered<br />

(for example #include). This header is<br />

inserted before the model’s simulation<br />

script. You can define the header for<br />

the active model only or as a default<br />

(select «Use as default»).