13<br />

414 Simulator<br />

2 How to use a state file<br />

Conditions:<br />

When you start the simulator, the «Start with Simulation State» dialog opens under the following<br />

conditions:<br />

• The state file is located in the model directory of the simulation model and has the same<br />

name as the simulation model (Model_name.krn).<br />

• The simulation model has not changed since the last saving of the state file.<br />

• The «State: load automatically» option in OPTIONS>SIMULATOR SETTINGS of the SSC Commander<br />

or on the Simulator Toolbar must be checked.<br />

If these conditions are met,<br />

the dialog «Start with Simulation<br />

State» opens when<br />

you start the simulator.<br />

You can open another state<br />

file by clicking the symbol.<br />

Model:<br />

Name of model file (SML<br />

source file).<br />

State file options for simulation start<br />

State file:<br />

Name of state file used for simulation with the stored simulation state.<br />

Created:<br />

Date of state file creation.<br />

Tbeg:/Tend:<br />

Simulation start time [s]./Simulation end time [s].<br />

3 Define the new simulation end time and start the simulation with . If you click<br />

, the values from the .sml source file are used.<br />

The new simulation end time Tend must be greater than the start time Tbeg. If not, when you<br />

click , you will see an error message.<br />

Using Initial Values<br />

1 Save initial values<br />

• Save file manually<br />

The SAVE INITIAL VALUES command in the simulator menu creates the file<br />

Model_name.aws. You can change the file name in the Windows file save dialog. Please<br />

note that this file must be placed in the model directory.<br />

• Save state automatically<br />

If the «Automatically Save Initial Values» option in OPTIONS SIMULATOR SETTINGS of the<br />

the SSC Commander or the Simulator Toolbar is checked, the file with initial values is<br />

saved automatically.