382 Simulation Results<br />

Time Window<br />

The «Automatic» option carries out the calculation the complete simulation time. If the box<br />

is clear, you can define your own calculation window.<br />

Filter Amplitude [%]<br />

Amplitudes smaller than the defined proportional value of the maximum are not displayed.<br />

Percent Evaluation<br />

If the box is selected, the maximum amplitude value is set to 100%; otherwise the value entered<br />

in the field is used.<br />

Result<br />

Select «Absolute Value and Phase» or «Real and Imaginary Part» for the representation of<br />

the results.<br />

Window<br />

Select the Rectangle, Triangular, Von-Hann, Hamming, Blackmann, Lanzcos, or Weber window<br />

from the list. Select the rectangular window if you want to investigate a periodical signal.<br />

Channel Calculator<br />

The Channel Calculator carries out mathematical operations with quantities connect to the<br />

pins and provides the result at one of the five output pins. In the sense of <strong>SIMPLORER</strong> Display<br />

Elements the Channel Calculator represents a connect element.<br />

Name<br />

Defines the channel name used in Connect View Elements.<br />

Expression<br />

Click the expression field and open the edit dialog (…) to define mathematical expressions.<br />

You can use only quantities connected to the input channels. Double-click a input name in<br />

the calculator dialog list to insert the name in the input field.<br />

12.2.3 Other Elements<br />

File Launcher<br />

In Addition to the View and postprocessing Display Elements there are the File Launcher and<br />

Data Channels. The File Launcher is used to start other applications when a defined condition<br />

becomes true. Data Channels provide a quantity of the simulation sheet to an Connect Display<br />

Element. Besides you can save simulation data of Display Elements in a .mdx file.<br />

The File Launcher starts a specified file when a certain condition becomes or is true. You can<br />

select the frequency of starting with the Start Mode. The Connect Element has five inputs to<br />

connect channels with quantities. In the expression dialog you can select connected channels<br />

with a double-click.<br />

Expression<br />

Create, delete or move a entry with the icons placed on the upper right side. Click the expression<br />

field and open the edit dialog (…) to define a logical expression. You can use all quantities<br />

used in the simulation model. In a connect element you can use only quantities connected to<br />

input channels. Double-click the quantity/input name in the edit dialog list to insert the values<br />

in the input field.