Magnetic Flux Source<br />

<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 317<br />

>>Basics>Physical Domains>Magnetic<br />

The component represents an ideal magnetic flux source which supplies the defined magnetic<br />

flux for an arbitrary magneto-motive force. Within the dialog you can choose a constant or<br />

time-controlled source.<br />

Dialog Settings<br />

� «Magnetic Flux [Vs]»<br />

The linear magnetic flux source is selected. Common parameter type. Enter a numerical value,<br />

a variable, or an expression in the text box or use the pin to connect a quantity.<br />

� � «Use pin»<br />

If the box is checked, the value is defined by the quantity connected to the pin, otherwise the<br />

value in the text box is used.<br />

� «Time Controlled»<br />

The time-controlled flux source is selected. In the list, select a time function and define the<br />

corresponding parameters. See also “Using Time Functions” on page 275.<br />

� In the list, select the sine, pulse, triangular, trapezoidal, saw-tooth rising, or saw-tooth falling<br />

time function.<br />

Linear Magnetic Flux Source<br />

FLUX() t =<br />

VALUE<br />

The magnetic flux is equivalent to the present value of the quantity specified in the text box.<br />

Usually a constant value, a time function, or a variable are chosen, or the value is determined<br />

in a state graph. All system quantities and variables can be combined with mathematical and<br />

logical operators and constants.<br />

The magneto-motive force of an ideal flux source can be arbitrary. Real flux sources have always<br />

an internal resistance. If the internal resistance is essential for the simulation target, a<br />

corresponding resistance must be connected in parallel.<br />

Component Parameters<br />

Description [Unit] Parameter Name Data Type<br />

Magnetic Flux [Vs] VALUE real<br />

Component Outputs<br />

Description [Unit] Parameter Name Data Type<br />

Magnetic Voltage [A] MV real<br />

Magnetic Flux [Vs] FLUX real<br />

Component Nodes<br />

Description Node Name Nature<br />

Pin 1 (with red point) MAG1 magnetic<br />

Pin 2 MAG2 magnetic