10.12.2012 Views

SIMPLORER User Manual V6.0 - FER-a

SIMPLORER User Manual V6.0 - FER-a

SIMPLORER User Manual V6.0 - FER-a

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Load Reference Arrow System of Circuit Components<br />

<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 535<br />

The counting direction of current and voltage is marked by the red point or the plus sign at<br />

the symbol of electrical components.<br />

Electrical<br />

Meters<br />

Network Configurations<br />

In <strong>SIMPLORER</strong> only ammeters are allowed as controlling components for current controlled<br />

elements. These must be inserted properly in the controlling branch. If sources are part of mutual<br />

controlling sources in the circuit, stability problems may occur if the total gain of the loop<br />

is greater than or equal to one.<br />

The following types of network configurations are invalid:<br />

• Series connection of ideal current sources<br />

• Series connection of inductors and ideal current sources<br />

• Series connection of inductors with different initial values of current, I01≠I02 • Series connection of an inductor with an initial current value and an opened ideal switch<br />

or nonconducting system level semiconductor<br />

• Parallel connection of ideal voltage sources<br />

• Parallel connection of capacitors with ideal voltage sources<br />

• Parallel connection of capacitors with different initial values of voltage, V01≠V02 • Meches which consist only of ideal sources (short-circuit)<br />

• Open-ended branches<br />

Actions in States<br />

Voltage Sources Current Sources Passive Components<br />

V<br />

i<br />

EMF+<br />

N1 N2<br />

-<br />

N1 N2<br />

Voltmeter Ammeter Wattmeter<br />

V<br />

+<br />

N1<br />

V<br />

i=0<br />

N2<br />

V<br />

i<br />

V<br />

N1 N2<br />

V=0<br />

+<br />

i<br />

W<br />

A NA1 NA2<br />

N1 N2<br />

NV1<br />

V i<br />

NV2<br />

Action Description Syntax in Value<br />

CALC The variable is calculated at each simulation step and<br />

each transition from one state to another.<br />

var1:=100*t<br />

STEP The variable is calculated at each valid simulation step. var2:=2*t<br />

CATI The variable is calculated outside the state graph and before<br />

the calculation of the electric circuit.<br />

var3:=sqrt(t)<br />

SET The variable is calculated only once at the moment of acti- var4:=2.5<br />

vation of the state.<br />

i