92 Modeling with Circuit Components<br />

Component Outputs<br />

Description [Unit] Parameter Name Data Type<br />

Voltage [V] V real<br />

Current [A] I real<br />

Source Current [V] IS real<br />

Derivative of Voltage [V/s] dV real<br />

Derivative of Current [A/s] dI real<br />

Component Nodes<br />

Description Node Name Nature<br />

Pin 1 (with red point) N1 electrical<br />

Pin 2 N2 electrical<br />

Controlled Current Source<br />

>>Basics>Circuit>Sources<br />

The component represents a dependent current source. You can choose a voltage-controlled,<br />

current-controlled, nonlinear voltage-controlled, or nonlinear current-controlled type.<br />

Dialog Settings<br />

� «Type»<br />

In the list, select the voltage-controlled, current-controlled, nonlinear voltage-controlled,<br />

nonlinear current-controlled type, or the Collector source.<br />

«Control Component»<br />

The voltage/current of the defined circuit component controls the value of the source. Quantity<br />

parameter type. The type accepts only voltage and current of voltmeters, ammeters, or<br />

wattmeters (e.g. VM1.V, AM2.I). The values cannot be assigned by a variable. Enter the<br />

quantity of a meter or use the pin to connect the quantity.<br />

� � «Use pin»<br />

If the box is checked, the control component is defined by the quantity connected to the pin,<br />

otherwise the name in the text box is used.<br />

«Factor»<br />

Only for linear controlled sources. The value of the control component is multiplied by the factor.<br />

The value '1' means the original value is used. Common parameter type. Enter a numerical<br />

value, a variable, or an expression in the text box or use the pin to connect a quantity.<br />

� � «Use pin»<br />

If the box is checked, the factor is defined by the quantity connected to the pin, otherwise the<br />

value in the text box is used.<br />

«Characteristic»<br />

Only for nonlinear controlled sources. IS=f(v) -> voltage-controlled, IS=f(i) -> current-controlled.<br />

Open the characteristic dialog or use the pin to define a characteristic. See also “Separate<br />

Component Characteristic” on page 297.<br />

� � «Use pin»<br />

If the box is checked, the voltage source is defined by the characteristic connected to the pin,<br />

otherwise by the settings in the dialog .