9<br />

286 Modeling Tools<br />

Delay within the Period [s] T0 real<br />

Periodical PERIO real<br />

Offset OFF real<br />

Initial Delay [s] TDELAY real<br />

Component Outputs<br />

Description [Unit] Parameter Name Data Type<br />

Needle Pulse Function VAL real<br />

Controlled Oscillator<br />

>>Basics>Tools>Time Functions<br />

yt () = AMPL ⋅ sin(<br />

360° ⋅ f + PHASE)<br />

f = fCTRL ( )<br />

f = UL when UL< CTRL<br />

f = LL when LL> CTRL<br />

Dialog Settings<br />

� «Limit Input Signal»<br />

Each value of the input signal, which controls the frequency of the output signal, is accepted.<br />

� «Limit Input Signal»<br />

If the box is checked, you can enter an upper and lower limit in the corresponding text box.<br />

Values outside of the range are ignored.<br />

«Upper Limit»«Lower Limit»<br />

Common parameter type. Enter a numerical value, a variable, or an expression in the text box.<br />

«Output Amplitude»<br />

Defines the amplitude of the sine wave. Common parameter type. Enter a numerical value, a<br />

variable, or an expression in the text box.<br />

«Phase»<br />

Defines the phase shift of the sf the created sine wave. Common parameter type. Enter a numerical<br />

value, a variable, or an expression in the text box.<br />

«Angular Dimension»<br />

In the list, select radians or degrees. The dimension is applied to the phase.<br />

Component Parameters<br />

Description [Unit] Parameter Name Data Type<br />

Input Signal CTRL real<br />

Input Signal Upper Limit UL real<br />

Input Signal Lower Limit LL real<br />

Amplitude AMPL real<br />

Phase [deg] PHASE real