10.12.2012 Views

SIMPLORER User Manual V6.0 - FER-a

SIMPLORER User Manual V6.0 - FER-a

SIMPLORER User Manual V6.0 - FER-a

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Linear Two-winding Transformer<br />

<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 189<br />

� � «Use pin»<br />

If the box is checked, the coupling factor is defined by the quantity connected to the pin, otherwise<br />

the value in the text box is used.<br />

Component Parameters<br />

Description [Unit] Parameter Name Data Type<br />

Inductance L1 [H] L1 real<br />

Initial Current L1 [A] I01 real<br />

Inductance L2 [H] L2 real<br />

Initial Current L2 [A] I02 real<br />

Coupling Factor [/] K real<br />

Component Outputs<br />

Description [Unit] Parameter Name Data Type<br />

Voltage L1 [V] V1 real<br />

Voltage L2 [V] V2 real<br />

Current L1 [A] I1 real<br />

Current L2 [A] I2 real<br />

Flux Linkage L1 [Vs] PSI1 real<br />

Flux Linkage L2 [Vs] PSI2 real<br />

Mutual Inductance [H] M real<br />

Derivative of Voltage L1 [V/s] dV1 real<br />

Derivative of Voltage L2 [V/s] dV2 real<br />

Derivative of Current [A/s] dI1 real<br />

Derivative of Current [A/s] dI2 real<br />

Derivative of Flux Linkage L1 [V] dPSI1 real<br />

Derivative of Flux Linkage L2 [V] dPSI2 real<br />

Component Nodes<br />

Description Node Name Nature<br />

Inductor 1 – Node N1 and N2 N1L1, N2L1 electrical<br />

Inductor 2 – Node N1 and N2 N1L2, N2L2 electrical<br />

>>Basics>Circuit>Transformers>Single-Phase Systems<br />

The component represents a transformer based on the Spiro model. For each coil make sure a<br />

network path exists to the ground node. The macro does not permit an access to the initial<br />

value of currents, these are assumed to be zero. Within the dialog you can define the main and<br />

leakage inductances, the equivalent resistances for iron losses and the winding resistances<br />

for each side.<br />

W 2<br />

KTR = ------- with W1 = Windings Primary Side and<br />

W1 =<br />

Windings Secondary Side<br />

W 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!