10.12.2012 Views

SIMPLORER User Manual V6.0 - FER-a

SIMPLORER User Manual V6.0 - FER-a

SIMPLORER User Manual V6.0 - FER-a

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Nonlinear Transfer Function<br />

>>Basics>Blocks>Signal Processing<br />

The block represents a nonlinear transfer behavior.<br />

<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 231<br />

«Input Signal»<br />

Enter a quantity name used in your model sheet in the text box to define the input signal<br />

(RLOAD.I, STEP.VAL, STATE.ST, VAR) or use the pin to connect a quantity. Please note: You<br />

cannot use conservative nodes from circuits as input signal (N0002, GND).<br />

� � «Use Pin»<br />

If the box is checked, the input signal is defined by the quantity connected to the pin, otherwise<br />

the value in the text box is used.<br />

Component Parameters<br />

Description [Unit] Parameter Name Data Type<br />

Discretization Quantity K real<br />

Input Signal INPUT real<br />

Sample Time [s] TS real<br />

Component Outputs<br />

Description [Unit] Parameter Name Data Type<br />

Block output signal VAL real<br />

yk ( ) =<br />

fxk ( ( ) )<br />

Dialog Settings<br />

«Characteristic»<br />

To describe the nonlinear relation, you must specify a name of an appropriate XY nonlinear<br />

characteristic function. See also “Separate Component Characteristic” on page 297.<br />

To define characteristic data you can do one of the following:<br />

• «Use Pin»; the XY component, connected to the pin, provides the characteristic.<br />

Within the Characteristic dialog:<br />

• «Reference»; the name in the text box specifies an XY element placed on the sheet.<br />

• «Lookup Table»<br />

a. «File Reference»; the name in the text box specifies a variable which refers to a subsheet<br />

port specifying a characteristic file.<br />

b. «Lookup Table»; data pairs, defined in the table, are used for characteristic.<br />

• � «File Name»; if you use an file, data pairs are displayed in the lookup table and used<br />

for characteristic. You can modify the data when necessary.<br />

� «Sample Time»<br />

Select «System» for simulator-defined variable sample time. Select «Value» to define a numerical<br />

value, a variable, or an expression in the text box or use the pin to connect a quantity.<br />

Please note: The sample time must be a positive value.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!