<strong>SIMPLORER</strong> 6.0 — <strong>Manual</strong> 85<br />

� «Time Controlled»<br />

The predefined time-controlled voltage source is selected. In the list, select a time function<br />

and define the corresponding parameters. These are Common parameter types. Enter a numerical<br />

value, a variable, or an expression in the text box. See also “Separate Component<br />

Characteristic” on page 297.<br />

� In the list, select the sine, pulse, triangular, trapezoidal, saw-tooth rising, or saw-tooth falling<br />

time function.<br />

� � «Spice Compatible»<br />

If the box is checked, the spice compatible reference arrow system is applied to the source.<br />

AC Parameters<br />

� «Phase & Magnitude»<br />

The Phase/Magnitude representation is selected. Common parameter types. Enter a numerical<br />

value, a variable, or an expression in the text box. See also “AC Simulation Models” on<br />

page 401.<br />

� «Angular Dimension»<br />

In the list, select radians or degrees for the angular dimension of the phase.<br />

� «Real & Imaginary»<br />

The Real/Imaginary representation is selected. Common parameter type. Enter a numerical<br />

value, a variable, or an expression in the text box.<br />

Linear Voltage Source<br />

vt () =<br />

– EMF<br />

The value of the electromotive force (EMF) is equivalent to the present value of the quantity<br />

specified in the text box. Usually a constant value, a time function, or a variable are chosen,<br />

or the value of the electromotive force is determined in a state graph. All system quantities<br />

and variables can be combined with mathematical and logical operators and constants.<br />

However, the expression must be technically meaningful. If it is not, numerical instability or<br />

completely wrong results are possible. In particular, sudden changes in the first derivation of<br />

the control quantity should be avoided.<br />

The <strong>SIMPLORER</strong> voltage sources have the opposite orientation compared to SPICE-like voltage<br />

sources. See also “Load Reference Arrow System of Circuit Components” on page 71.<br />

The current through an ideal voltage source can be arbitrary. Real voltage sources have always<br />

an internal resistance. If the internal resistance is essential for the simulation target, a<br />

corresponding resistance must be connected in series.<br />

Component Parameters<br />

Description [Unit] Parameter Name Data Type<br />

EMF Value [V] EMF real<br />

Partial Derivation Flag (1: On; 0: Off) PARTDERIV real<br />

EMF Magnitude [V] AC_MAG real<br />

EMF Phase Shift [deg] AC_PHASE real