A.4 Troubleshooting<br />

Modeling<br />

• Project must be copied before you can work with it<br />

Please remove the write protection from your files.<br />

• Cannot connect elements on a sheet<br />

<strong>SIMPLORER</strong> schematic checks that the types of two pins to be connected are correct,<br />

e.g,. it is not possible to connect an electrical pin to a signal pin. So please check that you<br />

are connecting the proper pin types. If the connection is still impossible, please place the<br />

same element again.<br />

• Connections are muddled<br />

Select the muddled wires, click the right mouse button and select «Disconnect» from the<br />

pop-up menu.<br />

• Errors in the SML Syntax<br />

Using comma as decimal point is not allowed.<br />

Logic operators must surrounded by spaces.<br />

Predefined variables cannot be used for names in a model description!<br />

When using functions, there should be no space between the function argument and the<br />

open parenthesis mark.<br />

Names for variables and elements are case sensitive. Please check the style.<br />

• Errors in the modeling<br />

Each independent circuit has to be connected to the ground node at least once. Only<br />

electrically reasonable circuits lead to correct simulation results. Voltage sources, current<br />

sources and switches are ideal components.<br />

Display and Simulation<br />

• No graphic is displayed<br />

It is possible that you did not define any outputs for a component (right mouse click and<br />

select Output) or you did not select the values to display in a Display Element.<br />

Please check the settings in EDIT>PROPERTIES. Check also, if the View Tool Window is<br />

reduced to a symbol in the Windows task bar. Restore it with the menu item «Restore».<br />

• Simulation does not start<br />

Please check the simulation queue in the SSC Commander. Here you will see all active<br />

jobs. All simulations are placed in this queue and processed according the start time.<br />

Another possibility is that the simulator window is still open in the task bar. If so, please<br />

close it.<br />

• Unexpected simulation results<br />

If the controlled sources are part of closed control loops in the circuit, stability problems<br />

can occur if the total gain of the loop is greater than or equal to one. In this case, (linearly<br />

or non linearly) controlled sources which directly access variables from the set or circuit<br />

equations should be used.<br />

• The simulator computes always with the maximal step width (HMAX)<br />

If the simulation model only consist of blocks, the block diagram is computed (to each<br />

time step) with the maximal step width (HMAX).