E. Inserts, Bolts, and Fasteners: Hot-dip galvanized according to ASTM A 153/A 153M.<br />

F. Grout: ASTM C 476, except with a maximum slump of 4 inches, as measured<br />

according to ASTM C 143/C 143M.<br />

2.2 STANDARD HOLLOW METAL DOORS<br />

A. General: Provide doors of design indicated, not less than thickness indicated;<br />

fabricated with smooth surfaces, without visible joints or seams on exposed faces unless<br />

otherwise indicated. Comply with ANSI/SDI A250.8.<br />

1. Design: Flush panel.<br />

2. Core <strong>Construction</strong>: Manufacturer's standard kraft-paper honeycomb,<br />

polystyrene, polyurethane, polyisocyanurate, mineral-board, or vertical steelstiffener<br />

core.<br />

a. Fire Door Core: As required to provide fire-protection ratings indicated.<br />

b. Thermal-Rated (Insulated) Doors: Where indicated, provide doors<br />

fabricated with thermal-resistance value (R-value) of not less than 4.0<br />

deg F x h x sq. ft./Btu when tested according to ASTM C 1363.<br />

1) Locations: Exterior doors.<br />

3. Vertical Edges for Single-Acting Doors: Manufacturer's standard.<br />

4. Top and Bottom Edges: Closed with flush or inverted 0.042-inch- thick, end<br />

closures or channels of same material as face sheets.<br />

5. Tolerances: Comply with SDI 117, "Manufacturing Tolerances for Standard Steel<br />

Doors and Frames."<br />

B. Exterior Doors: Face sheets fabricated from metallic-coated steel sheet. Provide doors<br />

complying with requirements indicated below by referencing ANSI/SDI A250.8 for level<br />

and model and ANSI/SDI A250.4 for physical performance level:<br />

1. Level 2 and Physical Performance Level B (Heavy Duty), Model 1 (Full Flush).<br />

C. Interior Doors: Face sheets fabricated from cold-rolled steel sheet unless metalliccoated<br />

sheet is indicated. Provide doors complying with requirements indicated below<br />

by referencing ANSI/SDI A250.8 for level and model and ANSI/SDI A250.4 for<br />

physical performance level:<br />

1. Level 2 and Physical Performance Level B (Heavy Duty), Model 1 (Full Flush).<br />

a. Provide doors of metallic-coated sheet steel at pool area rooms.<br />

D. Hardware Reinforcement: Fabricate according to ANSI/SDI A250.6 with reinforcing<br />

plates from same material as door face sheets.<br />

E. Fabricate concealed stiffeners and hardware reinforcement from either cold- or hotrolled<br />

steel sheet.<br />

Project No.: 10145 HOLLOW METAL DOORS AND FRAMES<br />