10. Latch bolt operated by inside lever at all times.<br />

11. When deadbolt is projected, all keys except emergency keys must be<br />

inoperable.<br />

12. Emergency key also acts as a lockout key.<br />

13. Inside lever must retract the latch bolt and deadbolt simultaneously.<br />

B. Finish: US26D Satin Chrome.<br />

PART 3 - EXECUTION<br />

3.1 INSPECTION<br />

A. Installer shall inspect doors and areas where equipment is to be applied and notify in<br />

writing of unsatisfactory conditions. Do not proceed with installation until<br />

unsatisfactory conditions have been corrected.<br />

3.2 INSTALLATION<br />

A. Comply with manufacturer’s written instructions and recommendations for installation<br />

of system components.<br />

B. Install electronic lock units at the following locations and as directed:<br />

1. Guestroom entry doors.<br />

2. Guest use areas.<br />

3. Back of house areas, as indicated.<br />

4. Entry doors, as indicated.<br />

C. Adjust operation of units in place to ensure proper latching and locking.<br />

3.3 DEMONSTRATION<br />

A. Provide instruction to Owner’s personnel to ensure that the system is operated<br />

properly. This training shall be accomplished before owner’s personnel are allowed to<br />

operate the system, and shall occur at project site.<br />

END OF SECTION 08 7200<br />

Project No.: 10145 GUESTROOM LOCKING SYSTEM<br />

550 15th Street Dual Brand Hotel 087200 - 2<br />

19 March 2012