1.1 SUMMARY<br />

SECTION 13 1500<br />

SWIMMING POOL<br />

A. Pool construction shall be provided on a design/build basis for work of this Contract.<br />

All systems shall be designed and installed in strict accordance with local, State and<br />

Federal laws, codes and ordinances in addition to the current Homewood Suites and<br />

Hampton USA Design & <strong>Construction</strong> Standards.<br />

B. Submit complete design/build plans and specifications for pool construction and<br />

systems as required to complete the work. Contractor is responsible for all facets of<br />

design and construction of all pool related systems.<br />

C. All drawings, calculations and submittals required to execute the design/build work of<br />

this Contract shall be sealed by an Engineer licensed in the State of Colorado.<br />

D. Submit one copy of submittals to Architect for information only. Submit additional<br />

submittals to Owner and Hilton for review and approval.<br />

1.2 GENERAL DESIGN CRITERIA<br />

A. Pool shall be constructed in accordance with “Minimum standards for public swimming<br />

pools” as published by the National Spa and Pool Institute.<br />

B. Fiberglass and stainless steel pools/whirlpools are not acceptable.<br />

C. The pool shall have a minimum depth of water in the shallow end of the main<br />

swimming area of between 3’-0” and 3’-6”. The depth of the deep end shall be a<br />

maximum of 5’-0”.<br />

D. Pool shall have at least two sets of ladders, stairs, steps, recessed steps or a<br />

combination thereof, located so as to fully serve both ends of the pool for purposes of<br />

entry and exit. Steps and handrail at the shallow end, ladder at the deep end.<br />

E. Hydraulic therapy lifter, stainless steel frame with a capacity to support 400 pounds<br />

with the horizontal arm fully extended. Provide lifter and all components required for a<br />

complete and operational installation. Provide sleeves in deck at pool.<br />

F. Actual pool depths must be measured and verified prior to marking the pool deck and<br />

sides. Lettering must be at least four inches high. Depths shall be in both English and<br />

metric units, English units shall be shown above the metric units.<br />

G. Pool Safety Equipment: Provide at least on shepherd’s hook or pole with a minimum<br />

length of 12 feet. Provide at two 24-inch life rings that have a United States Coast<br />

Guard approval. In addition, each life ring shall be attached to a line with a minimum<br />

diameter of 3/16-inch; the length of the life line shall be 1½ times greater than the<br />

greatest width of the pool. Provide a 16 unit first aid kit.<br />