PART 1 – GENERAL<br />

1.01 DESCRIPTION OF WORK:<br />

Project No.: 10145<br />

550 15 th Street Dual Brand Hotel<br />

03/16/2012<br />

SECTION 23 0553<br />

MECHANICAL IDENTIFICATION<br />

A. Extent of mechanical identification work required by this Section is indicated on the<br />

drawings and/or specified in other Division 23 sections.<br />

B. Types of identification devices specified in this section include the following:<br />

1.02 QUALITY ASSURANCE:<br />

1. Painted Identification Materials<br />

2. Plastic Pipe Markers<br />

3. Plastic Tape<br />

4. Underground-Type Plastic Line Marker<br />

5. Plastic Duct Markers<br />

6. Valve Tags<br />

7. Valve Schedule Frames<br />

8. Engraved Plastic-Laminate Signs<br />

9. Plastic Equipment Markers<br />

10. Plasticized Tags<br />

A. Manufacturer's Qualifications: Firms regularly engaged in manufacture of identification<br />

devices of the types and sizes required, whose products have been in satisfactory use in<br />

similar service for not less than 5 years.<br />

B. Codes and Standards:<br />

1.03 SUBMITTALS:<br />

1. ANSI Standards: Comply with ANSI A13.1 for lettering size, length of color field,<br />

colors, and viewing angles of identification devices.<br />

A. Product Data: Submit manufacturer's technical product data and installation instructions<br />

for each identification material and device required.<br />

B. Schedules: Submit valve schedule for each piping system, typewritten and reproduced on<br />

8-1/2” x 11” bond paper. Tabulate valve number, piping system, system abbreviation (as<br />

shown on tag), location of valve (room or space), size of valve, and variations for<br />

identification (if any). Only tag valves which are intended for emergency shut-off and<br />

similar special uses, such as valves to isolate individual system risers and individual floor<br />

branches, and building system shut-off valves. In addition to mounted copies of the valve<br />

schedules, furnish extra copies for Operating and Maintenance Manuals as specified in<br />

Division 23.<br />

23 0553 - 1 IDENTIFICATION FOR HVAC PIPING<br />

AND EQUIPMENT