1. Drainage Piping Specialties, including backwater valves, expansion joints, drains,<br />

cleanouts, trap primers, flashing flanges and vent flashing sleeves:<br />

Project No.: 10145<br />

550 15 th Street Dual Brand Hotel<br />

03/16/2012<br />

a. Josam<br />

b. Jay R. Smith<br />

c. Zurn<br />

d. Wade<br />

e. Woodford<br />

f. Precision Plumbing Products<br />

g. Sioux Chief<br />

2. Non-Metallic Trench Drains:<br />

a. ACO<br />

b. Quazite<br />

c. Josam<br />

3. Precast Concrete Basins and Manholes:<br />

a. Arco<br />

b. Copeland<br />

c. Amcor<br />

2.02 SANITARY AND STORM DRAINAGE, VENT AND SUBSURFACE DRAINAGE PIPE AND FITTINGS:<br />

A. General: Provide piping and pipe fittings complying with Division 22, Section 221116.<br />

2.03 BASIC SUPPORTS AND ANCHORS:<br />

A. General: Provide supports and anchors complying with Division 22, Section 220529.<br />

2.04 DRAINAGE PIPING SPECIALTIES:<br />

A. Provide drainage piping specialties as scheduled on the Drawings.<br />

B. Backwater Valves: Valve assembly shall be bronze-fitted cast iron, with bolted cover.<br />

Design shall provide for a maximum 1/4” clearance between flapper and seat for air<br />

circulation. Valve ends shall suit piping. Jay R. Smith Fig. 7012.<br />

C. Trap Primers: Bronze body valve with automatic vacuum breaker, with 1/2” connections<br />

matching piping system, and in compliance with ASSE 1018.<br />

1. Valves shall be easily adjusted to high or low pressure and shall be automatically<br />

activated whenever any faucet is opened in the building, causing a pressure drop.<br />

2. Connections: 1/2" NPT male inlet; 1/2" NPT female outlet.<br />

3. Valves shall be "Prime-Rite" Trap Primer Valve as manufactured by Precision<br />

Plumbing Products, Inc., or approved equal.<br />

4. When more than one (1) trap is to be primed, provide one or more distribution<br />

units as required by the manufacturer.<br />

22 1423 - 3 SANITARY & STORM DRAINAGE<br />

PIPING SPECIALTIES