Project No.: 10145<br />

550 15 th Street Dual Brand Hotel<br />

12/23/2011<br />

a. 3” and smaller: Type K soft drawn copper with wrought copper fittings,<br />

silver brazed solder joints.<br />

b. 4” and larger: Ductile iron, tar coated outside, cement mortar lined<br />

inside. Full lengths of pipe shall be utilized to the greatest extent possible.<br />

Fittings for ductile iron pipe shall be 350 psi pressure rated, tar coated<br />

outside and cement lined inside. Utilize rubber gasket joints.<br />

B. Sanitary Drainage and Vents – Inside Building:<br />

1. Above Grade: CISPI 301 cast iron, no-hub type, with neoprene gaskets and 300<br />

series stainless steel clamps; or DWV copper with wrought copper or cast brass<br />

fittings.<br />

2. Below Grade: For sizes 2” to 20”, ASTM A-74 service weight cast iron, hub-andspigot<br />

type only, with neoprene compression gaskets; or, for sizes 12” and larger,<br />

ductile cast iron with neoprene gasket joints.<br />

C. Sanitary Sewer – Beyond 5 feet Outside Building: ASTM D-2665 SDR-35 PVC Sewer Pipe;<br />

ductile cast iron with neoprene gaskets for sizes 12” and larger; or service weight cast iron,<br />

hub-and-spigot type, with neoprene gaskets.<br />

D. Roof Drainage – Inside Building:<br />

1. Above Grade: CISPI 301 cast iron, no-hub type, with neoprene gaskets and 300<br />

series stainless steel clamps; or schedule 40 galvanized steel pipe with galvanized<br />

cast iron drainage fittings and threaded joints. Full lengths of pipe shall be<br />

utilized to the greatest extent possible.<br />

2. Below Grade: For sizes 2” to 20”, ASTM A-74 service weight cast iron, hub-andspigot<br />

type, with neoprene compression gaskets; or, for sizes 12” and larger,<br />

ductile cast iron with neoprene gasket joints.<br />

E. Storm Sewer – Beyond 5 feet Outside Building: ASTM D-3034 SDR-35 PVC sewer pipe;<br />

ductile cast iron with neoprene gasket joints for sizes 12” and larger; or service weight cast<br />

iron soil pipe, hub-and-spigot type, with neoprene gaskets.<br />

F. Natural Gas Piping:<br />

1. Above Grade:<br />

a. Exposed locations:<br />

i. 2” and smaller: Schedule 40 black steel pipe, beveled ends, with<br />

150 psi malleable iron fittings and threaded joints.<br />

ii. Larger than 2”: Schedule 40 black steel pipe with seamless steel<br />

butt-weld fittings and welded joints.<br />

b. Inaccessible Locations:<br />

2. Below Grade:<br />

i. All sizes: Schedule 40 seamless black steel pipe, beveled ends,<br />

with socket-weld fittings same thickness as pipe, and welded<br />

joints.<br />

22 1116 - 8 BASIC PLUMBING PIPING