PART 1 – GENERAL<br />

1.01 DESCRIPTION:<br />

Project No.: 10145<br />

550 15 th Street Dual Brand Hotel<br />

03/16/2012<br />

SECTION 220523<br />

GENERAL DUTY VALVES FOR PLUMBING PIPING<br />

A. This Section describes general requirements for valves common to most plumbing piping<br />

systems which are specified elsewhere in Division 22.<br />

1.02 SUBMITTALS:<br />

A. Submit the following Product Data for all valves under provisions of Section 01300: Body<br />

material, valve design, pressure and temperature classification, end connection details,<br />

seating materials, trim material and arrangement, dimensions and required clearances,<br />

and installation instructions.<br />

B. Submit operating instructions and maintenance requirements for all valves.<br />

1.03 STANDARDS:<br />

A. All valves shall conform to applicable portions of the following standards and as required<br />

by the appropriate national and local codes.<br />

American National Standards Institute (ANSI)<br />

American Society of Mechanical Engineers (ASME)<br />

American Society for Testing and Materials (ASTM)<br />

American Welding Society (AWS)<br />

American Water Works Association (AWWA)<br />

Canadian Standards Association (CSA)<br />

Commercial Standards, National Bureau of Standards (CS)<br />

Compressed Gas Association (CGA)<br />

Copper Development Association (CDA)<br />

Federal Specifications (FS)<br />

Manufacturers Standardization Society (MSS)<br />

B. Solenoid valves shall be UL listed, FM/AGA/ANSI and CSA approved.<br />

1.04 DELIVERY, STORAGE, AND HANDLING:<br />

A. Prepare valves for shipping as follows:<br />

1. Ensure valves are dry and internally protected against rusting and galvanic<br />

corrosion.<br />

2. Protect valve ends against mechanical damage to threads, flange faces, and weld<br />

end preps.<br />

3. Set valves in best position for handling. Globe and gate valves shall be closed to<br />

prevent rattling; ball and plug valves shall be open to minimize exposure of<br />

220523 - 1 GENERAL-DUTY VALVES FOR<br />

PLUMBING PIPING