A. General: Provide engraving stock melamine plastic laminate, complying with FS L-P-387,<br />

in the sizes and thicknesses indicated, engraved with engraver's standard letter style of the<br />

sizes and wording indicated, black with white core (letter color) except as otherwise<br />

indicated, punched for mechanical fastening except where adhesive mounting is necessary<br />

because of substrate.<br />

B. Thickness: 1/8”, except as otherwise indicated.<br />

C. Fasteners: Self-tapping stainless steel screws, except contact-type permanent adhesive<br />

where screws cannot or should not penetrate the substrate.<br />

2.11 PLASTICIZED TAGS:<br />

A. General: Manufacturer's standard pre-printed or partially pre-printed accident-prevention<br />

tags, of plasticized card stock with matt finish suitable for writing, approximately 3-1/4" x<br />

5-5/8”, with brass grommets and wire fasteners, and with appropriate pre-printed<br />

wording including large-size primary wording (such as DANGER, CAUTION, DO NOT<br />

OPERATE).<br />

2.12 LETTERING AND GRAPHICS:<br />

A. General: Coordinate names, abbreviations and other designations used in mechanical<br />

identification work with corresponding designations shown, specified, scheduled and<br />

approved by the Owner/Engineer. Provide numbers, lettering and wording as indicated<br />

and approved by the Owner/Engineer for proper identification and<br />

operation/maintenance of mechanical systems and equipment.<br />

B. Multiple Systems: Where multiple systems of same generic name are shown and specified,<br />

provide identification which indicates individual system number as designated on the<br />

drawings or schedule as well as service.<br />

PART 3 – EXECUTION<br />

3.01 GENERAL INSTALLATION REQUIREMENTS:<br />

A. Coordination: Where identification is to be applied to surfaces which require insulation,<br />

painting or other covering or finish, including valve tags in finished mechanical spaces,<br />

install identification after completion of covering and painting. Install identification prior to<br />

installation of acoustical ceilings and similar removable concealment.<br />

3.02 DUCTWORK IDENTIFICATION:<br />

A. General: Identify air supply, return, exhaust, intake and relief ductwork and duct access<br />

doors with duct markers; or provide stenciled signs and arrows, showing ductwork service<br />

and direction of flow, in black or white (whichever provides the most contrast with<br />

ductwork color). Identification in an existing building shall match the method which exists<br />

in the building.<br />

B. Location: In each space where ductwork is exposed or concealed only by a removable<br />

ceiling system, locate signs near points where ductwork originates or continues into<br />

Project No.: 10145<br />

550 15 th Street Dual Brand Hotel<br />

03/16/2012<br />

23 0553 - 5 IDENTIFICATION FOR HVAC PIPING<br />

AND EQUIPMENT