1. Breakaway Device for Power-Operated Doors: Not more than 50 lbf required<br />

for a breakaway door or panel to open.<br />

E. Entrapment Force Requirements:<br />

1. Power-Operated Sliding Doors: Not more than 30 lbf required to prevent<br />

stopped door from closing.<br />

1.4 SUBMITTALS<br />

A. Product Data: For each type of product indicated. Include construction details,<br />

material descriptions, dimensions of individual components and profiles, and finishes<br />

for automatic entrances. Include rated capacities, operating characteristics, electrical<br />

characteristics, and furnished specialties and accessories.<br />

B. Shop Drawings: For automatic entrances. Include plans, elevations, sections, details,<br />

hardware mounting heights, and attachments to other work.<br />

1. Wiring Diagrams: For power, signal, and control wiring.<br />

2. Activation and safety devices.<br />

3. Include hardware schedule and indicate hardware types, functions, quantities,<br />

and locations.<br />

C. Samples for Verification: For each type of exposed finish required, in manufacturer's<br />

standard sizes.<br />

D. Product Certificates: For each type of emergency-exit automatic entrance, from<br />

manufacturer.<br />

E. Product Test Reports: Based on evaluation of comprehensive tests performed by a<br />

qualified testing agency, for automatic entrances.<br />

F. Maintenance Data: For automatic entrances, safety devices, and control systems to<br />

include in maintenance manuals.<br />

G. Warranties: Sample of special warranties.<br />

1.5 QUALITY ASSURANCE<br />

A. Manufacturer Qualifications: A manufacturer with company certificate issued by<br />

AAADM.<br />

B. Source Limitations for Automatic Entrances: Obtain automatic entrances from single<br />

source from single manufacturer.<br />

C. Electrical Components, Devices, and Accessories: Listed and labeled as defined in<br />

NFPA 70, by a qualified testing agency, and marked for intended location and<br />

application.<br />

D. Power-Operated Door Standard: BHMA A156.10.<br />

Project No.: 10145 AUTOMATIC ENTRANCES<br />

550 15th Street Dual Brand Hotel 084229 - 2<br />

19 March 2012