D. Panic Exit Devices: Listed and labeled by a testing and inspecting agency acceptable to<br />

authorities having jurisdiction, for panic protection, based on testing according to<br />

UL 305.<br />

E. Fire Exit Devices: Devices complying with NFPA 80 that are listed and labeled by a<br />

testing and inspecting agency acceptable to authorities having jurisdiction, for fire and<br />

panic protection, based on testing according to UL 305 and NFPA 252.<br />

F. Outside Trim: Lever with cylinder; material and finish to match locksets, unless<br />

otherwise indicated.<br />

1. Match design for locksets and latchsets, unless otherwise indicated.<br />

G. Available Manufacturers:<br />

1. Adams Rite Manufacturing Co. (ARM).<br />

2. DORMA Architectural Hardware (DAH).<br />

3. SARGENT Manufacturing Company; an ASSA ABLOY Group company (SGT).<br />

4. Von Duprin; an Ingersoll-Rand Company (VD).<br />

2.8 LOCK CYLINDERS<br />

A. Standard Lock Cylinders: BHMA A156.5, Grade 1.<br />

B. Cylinders: Manufacturer's standard tumbler type, constructed from brass or bronze,<br />

stainless steel, or nickel silver, and complying with the following:<br />

1. Number of Pins: Six.<br />

C. Manufacturer: Same manufacturer as for locks and latches.<br />

2.9 OPERATING TRIM<br />

A. Standard: BHMA A156.6.<br />

B. Materials: Fabricate from stainless steel, unless otherwise indicated.<br />

C. Available Manufacturers:<br />

1. Hager Companies (HAG).<br />

2. IVES Hardware; an Ingersoll-Rand Company (IVS).<br />

3. Rockwood Manufacturing Company (RM).<br />

4. Trimco (TBM).<br />

2.10 CLOSERS<br />

A. Accessibility Requirements: Where handles, pulls, latches, locks, and other operating<br />

devices are indicated to comply with accessibility requirements, comply with the U.S.<br />

Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities<br />

Act (ADA), Accessibility Guidelines for Buildings and Facilities (ADAAG)."<br />