OperationMAC mini iH Series Operation <strong>Manual</strong>6.2. Auto runThe following explains the steps to operate the table by the program into the memoryautomatically.6.2.1.Program selection Select to the program to be operated automatically.! When pushing 1MODE1, the mode is changedin order. Push this button several times until EDIT is selected (LED lighting). ! Select an auto run execution program. When the channel is changed, the block ofN000 is selected.When executed except block No. N000. ! Select the auto run execution block. 6.2.2.Mode selectionSelect the AUTO mode to perform the auto run.! When pushing 1MODE1, the mode is changedin order. Push this button several times until AUTO is selected (LED lighting).6.2.3.Program STARTPerform the auto run of program.When the program is executed from the pendant.+ ENABLE switch! Automatically operate the program by 1-blockcurrently displayed.The ENABLE switch is required only start.Even if operation is released during automaticoperation, it does not stop.When the program is executed from the external signal.Turn ON ST ofexternal START signal.! The operation content is the same as above. During auto run, STATUS RUN LED goes out and STOP lights. When the auto run by 1-block is completed, STATUS RUN LED goesout and STOP lights.O6-2 KITAGAWA