MAC mini iH Series Connection <strong>Manual</strong>Connection to Machine12 Connection to Machine12.1. Machine connection wiringThe system receives and transmits the start signal (M-signal) and 1 block finish signal from/to theexternal equipment.In addition to the above, since the following signals can be communicated, be sure to route the cablesfor their signals.★★★★★★★★★★START STThe program is executed by this signal during AUTO orSINGLE mode.STOP SPThough this signal is used as a temporary stop signal of program, since SP signal isB-contact specification even if this function is not used, it is necessary to be short-circuitedwith INCOM line.EXTERNAL EMERGENCY STOP EXTEMThis signal is used for inputting the emergency stop from the external equipment.INPUT COMMON INCOMThis the common line for an input signal.1 BLOCK FINISH BLKFINThis signal is outputted when 1 block motion is finished during AUTO mode.1 BLOCK FINISH COMMON BLKFINCOMThis is the common for 1 block finish output signal.ALARM OUTPUT B ALMOUTBThis is for issuing the alarm signal on the circular table side.OUTPUT COMMON OUTCOMThis is the common for output signal.EMERGENCY STOP OUTPUTEMOUTThis is for outputting the emergency stop button state of controller.EMERGENCY STOP OUTPUT COMMONEMOUTCOMThis is the common for emergency stop output signal. KITAGAWA C12-1