AlarmsMAC mini iH Serieses Maintenance <strong>Manual</strong>Detailed explanation on the alarm for Err.016PatternThe following shows a flowchart of troubleshooting for Err.016 that occurs when the power is ON, orduring clamp after table rotation.Error .016 occurredIs the pressuresource normal?NoCheck the pressure source.YesDid the air pressurereduce whenerror .016 occurred?NoYesPRM038=1YesNoError .016 occurs either when clamp pressuregoes below the detective pressure for 5seconds or more, or when unclamp signal iskept ON exceeding the set time for PRM023.Take measures to prevent the clamp pressurefrom going down.Error .016 occurs when pressure goes downexceeding the set time for PRM024 duringclamping.Did not the brakeoutput (DC24V)when clamping?NoPRM039=1NoMake the setup value PRM039= 1.See the checkingmethod 1YesYesInternal circuit is considered to be incorrect.Contact our the service department.See the checkingmethod 2Is the clamp checksignal (SP1) normal?YesNoEither a failure of clamp check pressure switchSP1, or breakdown of clamp wiring isconsidered.As for replacement, see the instructionmanual of NC circular table.Error .016 does not occur under this situation.Contact our service department if an alarm occurs.I1-28 KITAGAWA