MAC mini iH Series Maintenance <strong>Manual</strong>AlarmsErr. No.520Description of alarmVibration alarmC a u s e1. Abnormal vibration is detectedduring the motor rotation.2. The value of moment of inertia ishigher than real value. Or it changeswith great fluctuation.D e t a i l sC o u n t e r m e a s u r e sAbnormal vibration is detected during the motorrotation.1-1. Reduce the revolving speed.1-2. Reduce the speed loop gain (PRM510).2. Set the ratio of moment of inertia (PRM513) within anadequate range.710 Over load (Momentary maximum load) High load is rotated instantaneously.7207307407A0Over load (Continuous maximum load)1. Servo pack is broken.2. Motor wiring is incorrect.3. Encoder wiring is incorrect.4. Effective torque exceeds the ratedtorque.5. Startup torque exceeds either therated torque or the maximum torqueby a large margin.DB over load1. Servo pack substrate is broken.2. Rotating energy when dynamicbrake (DB) is shut down exceeds thecapacity of DB resistance.Inrush current limit resistance overload1. Servo pack substrate is broken.2. Inrush current resistance exceeds thelimit of permissible frequency whenthe main circuit power source isON/OFF.Heat sink overheat1. Servo pack substrate is broken.2. Servo pack substrate and thermoswitch are not connected properly.3. Servo pack fan stops.4. The load exceeds the rated load.5. The ambient temperature of theservo pack exceeds 55.Load is rotated for a certain period with a torqueexceeding the rating.1. Replace the servo pack.2. Correct the motor wiring.3. Correct the encoder wiring.4,5. Review the conditions for loading and operation.Rotating energy when dynamic brake (DB) is shutdown exceeds the capacity of DB resistance.1. Replace the servo pack.2-1. Reduce the working frequency for motor.2-2. Reduce the load moment of inertia.2-3. Reduce the occurrence of DB shutdown.Switch the main circuit power source ON/OFF at thefrequency that exceeds 10times/2min.1. Replace the servo pack.2. The number of times for the main circuit power source toswitch ON/OFF must be 5 times per min. or less.The temperature of the heat sink in the servo packexceeds 100.13. Replace the servo pack.4. Review the conditions for loading and operation.5. Lower the ambient temperature around the controller.KITAGAWA I1-23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!