AlarmsMAC mini iH Serieses Maintenance <strong>Manual</strong>Detailed explanation on the alarm for Err.016Pattern 2The following shows a flowchart of troubleshooting for Err.016 that occurs soon after the rotation starts orduring.Error .016 occurredYesIs the clamp outputnormal?YesNoSee the checking method 3Either internal circuit error or break down ofthe brake wiring is considered.Contact our service department if no errorwas detected in the wiring check.Was clamp signalchecked whenerror .016 occurred?YesPRM038=1NoError .016 occurs either when unclampsignal is kept OFF exceeding the set timefor PRM023 during unclamping.NoYesError .016 occurs when clamp signal iskept ON exceeding the set time forPRM024 during unclampingIf any abnormality above is not checked,internal circuit may be incorrect.Contact our the service department.Did the brake outputwhen unclamping?See the checkingmethod 4YesNoEither a failure of unclamp check pressureswitch SP2 or breakdown of unclamp wiringis considered.As for replacement, see the instructionmanual of NC circular table.Error .016 does not occur under this situation.Contact our service department if an alarm occurs.I1-30 KITAGAWA