External Channel Selection5.1.3.Binary listMAC mini iH Series Parameter・Expansion<strong>Manual</strong> Mark shows INPUT state (ON).5.1.4.Timing500msec or moreExternal channelExternal channel setChannel change finish100msecor moreBecause input time is 100msec.,external channel is not set.500msec PRM035Channel is changed at this time. External channel select INPUT signal is to be continuous 100msec., ormore by considering the chattering. External channel INPUT signal is to be continuous 500msec., or more byconsidering the chattering. After inputting CHSET signal, FIN OUTPUT is to be started at 500msec. BLK FIN OUTPUT time is to be time of PRM035.Precautions1. Channel does not change even if CHSET INPUT is turned ON, duringBLKFIN and G99FIN OUTPUT.2. When INPUT time of CHSET is 500msec or less, the channel does notchange.3. The timing to change the channel is after 500msec., from CHSELINPUT start.P5-2 KITAGAWA