MAC mini iH Series Maintenance <strong>Manual</strong>AlarmsCheck MethodC. Use the self-diagnostic function.Method Push(CL/DGN) to display self-diagnostic screen and pushtimes to check EA-0(Output signal for each axis).The above BRAKE ON shows the following information.0 : Non-excitationState of clamp1 : ExcitationState of unclampBRAKE ON(CL/DGN) sixCheck MethodD. Use the self-diagnostic function.Method Push(CL/DGN) to display self-diagnostic screen and pushtimes to check EA-1(Input signal for each axis).(CL/DGN) fourUNCLAMPCLAMPIn the case of the checking method 4, items shown below are normal.0 : Not detecting Clamp checked1 : Detecting Unclamp checkedPattern If Error .016 occurs when the power is ON and brake is not used (PRM032=1), take measures oftroubleshooting in the pattern 2 after the section of “Do you hear the exhaust sound when brake is OFF as forair?”.KITAGAWA I1-31