MAC mini iH Series Maintenance <strong>Manual</strong>AlarmsChecking MethodA. Use the self-diagnostic function.Method Push(CL/DGN) to display self-diagnostic screen and pushtimes to check EA-0(Output signal for each axis).The above BRAKE ON shows the following information.0 : Non-excitationClamped1 : ExcitationUnclampedBRAKE ON(CL/DGN) sixChecking MethodB. Use the self-diagnostic function.Method Push(CL/DGN) to display self-diagnostic screen and pushtimes to check EA-I(Input signal for each axis).UNCLAMPCLAMPIn the case of the checking method 2, items shown below are normal.0 : Not detecting Unclamp checked1 : Detecting Clamp checked(CL/DGN) four Clamp signal and unclamp signal never become 1 or 0 simultaneously under normal situation.However it could happen just for a moment when solenoid is changed.KITAGAWA I1-29