AlarmsMAC mini iH Serieses Maintenance <strong>Manual</strong>Err. No.217218219230800801803Description of alarmG99FIN time outC a u s e1. G99 check signal is not detectedwithin the set time for PRM028when PRM027=12. Either PRM028 is zero, or PRM029is other than 2, whenPRM027=1.(determined duringautomatic operation)Channel set alarm1. Channel setting becomes inadequatewhen external channel is changed.2. Channel number is not displayedwhen program is transferred.External mode selection error1. Wiring of AUTOSET orANUALSET is short-circuited.G09 execution axis error1. In the case of 2-axis controller, theaxes that were not used for G08command are used for G09command.Address error1. The display shows other than /A/ nor /B/when program is transferred.2. An address that does not exist istransferred.3. NC program is not enclosed with / or [ ]when remote controlled.NC axis command error1. /A/ or /b/ is displayed on the NCprogram transferred through remotecontrol single-axis specification.2. The letter behind / is not A,B, / or [ .NC set range over1. The set value of the NC programaddress is wrong when automaticoperation is performed.D e t a i l sC o u n t e r m e a s u r e sG99 check signal for handshake does not turn ONwithin the designated duration.1. See if G99FIN circuit functions properly.2. Check and correct the parameter.When channel select is executed at binary mode afterCHSET input, wrong channel is selected.1. Replace the controller (main board).2. Check the transfer content and send normal data.Input of the both external signals, AUTOSET andMANUALSET are detected.1. Check and correct the circuit of AUTOSET andMANUALSET.Replace the cable when CB3 cable is incorrect.Program error.1. Check the program and correct them so that the sameaxes as used for G08 command are used for G09command.The transfer program is inadequate.1,2. Check the transfer content and send normal data.3. Check the content of the remote program command andsend normal data.The transfer program is inadequate.1,2. Check the transfer content and send normal data.The transfer program is inadequate.1. Check the address of the sending program andsend normal data.I1-16 KITAGAWA

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!