10.07.2015 Views

User's Manual - Kitagawa Europe

User's Manual - Kitagawa Europe

User's Manual - Kitagawa Europe

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MAC mini iH Series Maintenance <strong>Manual</strong>AlarmsErr. No.Description of alarmC a u s eD e t a i l sC o u n t e r m e a s u r e s941 Program J-address input error The set value for J code in the program is wrong.942 Program F-address input error The set value for F code in the program is wrong.943 Program P-address input error The set value for P code in the program is wrong.944 Program A-address input error The set value for A code in the program is wrong.945 Program L-address input error The set value for L code in the program is wrong.946 Program D-address input error The set value for D code in the program is wrong.947 Program E-address input error The set value for E code in the program is wrong.9501. Input the wrong value for the programaddress.2. The address in the sending programthrough communication is wrong.Parameter range over1. Input a right value for the address.2. Check the transfer content program and send normaldata.Attempted to set an incorrect value to the parameter setarea.1. A wrong value is set for the parameter. 1. Input the value settable in the parameter range951952961CH block variable change error1. The total number of the blocksexceeds 2000 when PRM390 is not0.2. Program must be deleted whenPRM390 is set to 1.Block set error.1. The setting of the number of blocks inCHOO is 0 when PRM390 is not 0.2. When the channels used for CH00CH89 are not continuous.EDIT block copy error1. The starting block for G27 falls on thefinal block.2. The finishing block for G27 falls on thefinal block.3. Final block copy is executed when thedestination of jump is the final blockAn internal error1. Set the total number of blocks at 2000 or less.2. Backup the program if existing program is necessary.Set PRM390=2 if the program is not necessary.Wrong blocks are selected when setting an extensionchannel.1. When PRM390 is not 0, 0 cannot be set for CH00.2. Set the blocks to PRM400PRM489 of continuouschannels.A failure occurs in an automatic generation of block numberssuch as jump command during copying blocks.1,2. Check and correct the program for G27command block.3. Block cannot be copied at the final block.KITAGAWA I1-19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!