10.07.2015 Views

User's Manual - Kitagawa Europe

User's Manual - Kitagawa Europe

User's Manual - Kitagawa Europe

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

External Channel SelectionMAC mini iH Series Parameter・Expansion<strong>Manual</strong>5.2.3.Timing100msec100msec or moreZERO(CHSEL0)PLUS1(CHSEL1)PLUS10(CHSEL2)MINUS10(CHSEL3)Channelchange finish(BLKFIN) CHOUT0Channel is changed atthis point.CHOUT1CHOUT2CHOUT3CHOUT4CHOUT5CHOUT6PrecautionsCH00 CH10 CH20 CH30 CH31 CH32 CH22 An external channel select INPUT signal is to be continuous 100msec., ormore by considering the chattering.After inputting the external channel selection, FIN OUTPUT is to bestarted at 100msec.Since a BLK FIN OUTPUT is turned OFF after checking the channelselection INPUT OFF, the time of PRM035 is not outputted. Channel does not change even if the external channel selection INPUTis ON during BLKFIN and G99FIN OUTPUT. The channel does not change even if other channel is inputted duringexternal channel selection input. When the interval of 100msec or more is not checked after externalchannel selection OFF, the channel is not changed. The timing to change the channel is after 100msec., from EXCHSELINPUT start.P5-4 KITAGAWA

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!