10.07.2015 Views

User's Manual - Kitagawa Europe

User's Manual - Kitagawa Europe

User's Manual - Kitagawa Europe

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MAC mini iH Series Connection <strong>Manual</strong>I/O Signals8.1.2.8.RST signal ! Contents RESET mode is inputted by short-circuiting RST and INCOM. Operational contents is the same as aRESETa key on the panel and itis shown in the following list.! An alarm is released and the program is returned to top at EDITmode.! RESET operation varies by mode and status.Mode Status ContentAUTOEDITRUNRUN STOPSTOPRESETALARMPROGRAM STOPPROGRAM RESET & REWINDPROGRAM RESETPROGRAM REWINDALARM RESETPROGRAM REWIND! Conditions1. All RESET modes are to be valid.2. An RESET signal INPUT time is to be continuous 100msec or more.8.1.2.9.ZRN signalThe zero return INPUT signal is divided into two kinds (MZRN and WZRN byparameters) and it can be inputted for finishing to G99 OUTPU.ZRN1 shows A-axis and ZRN2 B-axis.8.1.2.10.MZRN ! Contents MZRN of A-axis is performed by short-circuiting ZRN1 and INCOM. MZRN of B-axis is performed by short-circuiting ZRN2 and INCOM.! Conditions1. PRM029 is 0. (PRM029=0)2. Only MANUAL mode is to be valid.3. ZRN signal INPUT time is continuous 100msec or more.KITAGAWA C8-7