MAC mini iH Series Connection <strong>Manual</strong>CB2i Cable5 CB2i Cable (External SOL Cable)Since the NC circular table of hydraulic clamp spec., is equipped with the solenoid valve for clampto the external equipment, it is necessary to output the power for clamping from the controller.In this case, the cable of CB2i is connected.The cable of CB2i is connected to the connector for the brake of main board in the controller.However, the voltage outputted for the external solenoid is used for only DC24V 0.5A.The CB2i cable is attached to only hydraulic clamp type. Other circular tables are not equipped withits cable.5000 100BRAKE11.25-YASS3.5CB2i cable is packed together with cable clamp parts.MAC mini iH/iHF / iHPCable Name Connector Pin No. Terminal Indication RemarksCB2i BRAKE1MAC mini iH2 / iHTCable Name Connector1 BK+1 DC24V Brake OUTPUT2 BK-1 DC24V Brake OUTPUTPin No.TerminalIndicationRemarksCB2iBRAKE11 BK+1 DC24V Brake OUTPUT for A-axis2 BK-1 DC24V Brake OUTPUT for A-axisCB2i2BRAKE21 BK+2 DC24V Brake OUTPUT for B-axis2 BK-2 DC24V Brake OUTPUT for B-axisKITAGAWA C5-1