COMPANY – CUSTOMER RESPONSIBILITY (CONTINUED)<br />

FIGURE 5-A<br />

COMPANY-CUSTOMER SERVICE RESPONSIBILITY<br />

FOR SECONDARY SERVICE GROUPED METER LOCATIONS<br />

METER<br />

SOCKET<br />

APPLICATION<br />

TYPICAL<br />

P.O.D. (1)<br />

LOCATION<br />

REF. COMPANY-CUSTOMER RESPONSIBILITY AT METER<br />

SOCKET AND SERVICE ENCLOSURES<br />

Overhead<br />

Secondary Service<br />

with 2 or more<br />

meters served<br />

from<br />

Overhead Xfmr.<br />

Service<br />

Head<br />

3-G,<br />

3-H<br />

Customer furnishes, installs, and connects conductors from<br />

service head(s) to service enclosure and from service enclosure<br />

to meter sockets.<br />

Customer furnishes and installs connectors in service enclosure<br />

as required.<br />

Underground<br />

Secondary Service<br />

with 2 or more<br />

meters served<br />

from<br />

Overhead Xfmr<br />

Service<br />

Enclosure or<br />

Meterpack (3)<br />

4-D,<br />

4-E,<br />

5-D<br />

Customer furnishes and installs conductors between meter<br />

sockets and service enclosure, supplies connectors when<br />

required, and makes connections in meter sockets and service<br />

enclosure.<br />

Company furnishes and installs service lateral conductor and<br />

connectors and makes connections on source terminals of<br />

service enclosure or meterpack (3).<br />

Underground<br />

Secondary Service<br />

with 2 or more<br />

meters served<br />

from<br />

Padmounted Xfmr<br />

Xfmr<br />

Terminals<br />

4-D,<br />

4-E,<br />

5-D<br />

Customer furnishes and installs conductors between meter<br />

sockets and service enclosure or meterpack (3) and transformer;<br />

supplies connectors when required; and makes connections in<br />

meter sockets, service enclosure and meterpack (3).<br />

Customer furnishes connectors. Company attaches connectors<br />

at source end and makes connections on transformer terminals.<br />

AT LOCATIONS OTHER THAN METERS FOR SECONDARY SERVICE LOCATIONS<br />

LOCATION<br />

Service<br />

Head<br />

Padmount<br />

Transformer<br />

Secondary<br />

Compartment<br />

Padmount<br />

Secondary<br />

Enclosure at<br />

Transformer Pad<br />

Company<br />

Handhole or<br />

Pedestal<br />

Secondary<br />

Service,<br />

I.T. Enclosure<br />

TYPICAL<br />

P.O.D. (1)<br />

LOCATION<br />

Service<br />

Head<br />

Pad Xfmr.<br />

Terminals<br />

Secondary<br />

Enclosure<br />

REF.<br />

3-D, 3-E,<br />

3-F, 3-G,<br />

3-H, 3I<br />

__<br />

__<br />

CONDUCTORS<br />

LOCATION<br />

OWNERSHIP<br />

CONNECTORS<br />

PROVIDED BY<br />

CONNECTIONS<br />

MADE BY<br />

Source Company Company Company<br />

Load Customer Company Company<br />

Terminals Company ___ ___<br />

Load Customer Customer Company<br />

Source Company Company Company<br />

Load Customer Customer Company<br />

Handhole<br />

Source Company Company Company<br />

or __<br />

Pedestal<br />

Load Customer Customer Company<br />

Source Customer (2) Customer Customer<br />

Pad Xfmr.<br />

Terminals __ Load Customer Customer Customer<br />

(1) P.O.D. = Point of Delivery as defined in 100.01.19, page 6.<br />

(2) For Customers served from an overhead transformer bank, the source side service lateral<br />

conductors will be provided by the Company and the P.O.D. will be the I.T. Enclosure.<br />