3. Make copies of reference standards available as requested by Engineer/<br />

Owner/CMAR.”<br />

SC‐3.03<br />

Make the following modifications to 3.03 Reporting and Resolving Discrepancies<br />

A. Delete Paragraph 3.03.A.3 entirely and insert the following in its place:<br />

3. “In the event of a conflict in the Drawings, Specifications, or other portions of the<br />

Contract Documents which were not reported prior to the <strong>Bid</strong>ding of the <strong>Bid</strong> Proposal,<br />

the <strong>Bid</strong>der shall be deemed to have included the most expensive item, system,<br />

procedure, etc. in his <strong>Bid</strong> Proposal.”<br />

SC‐3.03 Make the following modifications to 3.03 Reporting and Resolving Discrepancies<br />

A. Amend paragraph 3.03. A.1. of the General Conditions by striking out the following words:<br />

"; provided , however, that CMAR shall not be liable to Owner or Engineer for failure to<br />

report any such conflict, error, ambiguity or discrepancy unless CMAR knew or reasonably<br />

should have known thereof." and add the following:<br />

“In the event of a conflict in the Drawings, Specifications, or other portions of the Contract<br />

Documents which were not reported prior to the <strong>Bid</strong>ding of the <strong>Bid</strong> Proposal, the <strong>Bid</strong>der<br />

shall be deemed to have included the most expensive in his the <strong>Bid</strong> Proposal.”<br />

SC‐4.01<br />

Make the following modifications to 4.01 Availability of Lands<br />

A. Add the following to Paragraph 4.01.C:<br />

“A copy of the written agreements for the use of such land shall be provided to the Owner<br />

for record purposes.”<br />

SC‐4.02 Make the following modifications to 4.02 Subsurface and Physical Conditions<br />

As set forth in paragraph 4.02, Engineer OR Engineer's Consultants in the preparation of<br />

Drawings and Specifications have relied upon:<br />

A. Geotechnical Investigation Report by Freese and Nichols, Inc.<br />

“4.02.A.1 The following reports of explorations and tests of subsurface conditions at or<br />

contiguous to the site of the Work.<br />

4.02.A1.1 The report is in progress. The technical data contained in the report upon which<br />

the <strong>Bid</strong>der may rely is boring depth, boring logs, water levels. <strong>Bid</strong>der recognizes that the<br />

technical data listed reflect only the conditions for the day the data was collected and<br />

reflects only conditions existing at the exact location of Samples.<br />

B. Add the following paragraph.<br />

Supplementary Conditions (Revised per <strong>Garney</strong>)<br />

Colorado River Municipal Water District<br />

Ward County Water Supply Expansion Project - Pump Stations 00 73 00 - 6<br />

12/28/2011