practical and effective ways in determination of hydration status as easy and non-invasive<br />

methods for teakwondo athletes.<br />

Subjects<br />

Materials and Methods<br />

Elite international level sixteen female and sixteen male (total: 32) teakwondo athletes<br />

took part in this study to whom preparing Balkan Championship 2003, during 11 days of<br />

camp season. Their physical characteristics (Mean ± SD) in the beginning of the camp and<br />

before breakfast were; age, 16.9 ± 2 years; height, 163.0 ± 9.6 cm; body mass, 58.8 ± 9.7 for<br />

girls and 18.5 ± 2.6 years; height, 177.6 ± 9.3 cm; body mass, 66.3 ± 13.6 for boys. All<br />

subjects gave written informed consent before the study. Local ethic committee approval and<br />

written approval from the teakwondo federation was taken for this study. A short<br />

questionnaire and review was applied to all subjects before sample collection. Subjects had no<br />

known renal or urinary track disease.<br />

Test Procedures<br />

Beside the body mass measurements, urine osmolality, conductivity, colour and<br />

specific gravity measurements was made on the first urine specimen of the day which was<br />

collected after wakening but before breakfast. This was done on 3 occasions, at the beginning<br />

of the camp, half way through the camp (5 days after from first) and one day before the<br />

competition (5 days later from second). All collected urine samples first urine of the day to<br />

be excreted in to a container and kept in cold an aliquot (approximately 20 ml) for later<br />

analyses.<br />

As an indication of athlete’s hydration status, the urine osmolality was determined via<br />

freezing point depression (Osmomat 030, Gonotec, Berlin, Germany 1996). The urine SEC<br />

was measured by using a hand portative conductivity meter (Hanna HI-9835 Multi-range UK<br />

2003). The urine specific gravity of samples was determined by measuring system of<br />

refractometer using the otoanalyser of URISYS 2400 (Roche Diagnostics, Gmbh, Mannheim,<br />

Germany). The urine color was always determined by the same investigator by comparing the<br />

urine sample with a visual color gradation scale (1 – 8) in a well-lighted room (Amstrong<br />

1994).<br />

Statistical analyses<br />

The data from the three occasions were normally distributed and presented as means<br />

and SD (mean ± SD) in the text. One-Way ANOVA test and Tukey post hock was used to<br />

compare the data of 3 testing. Pearson Two-Tailed correlations were also done for all tested