• develop a detailed plan that relates to noise control for relevant work<br />

practices and discuss this with construction staff during health & safety<br />

briefings;<br />

• avoid dropping materials from height, where practicable;<br />

• avoid metal-to-metal contact on equipment;<br />

• avoid mobile plant clustering near residences and other sensitive land<br />

uses;<br />

• ensure periods of respite are provided in the case of unavoidable<br />

maximum noise level events;<br />

• inform all potentially impacted residents of the nature of works to be<br />

carried out, the expected noise levels and duration, as well as providing<br />

the contact details of the CLO;<br />

The following plant and equipment noise control strategies shall be<br />

considered, adopted and enforced where practicable:<br />

• ensure, where feasible and reasonable, that ‘low noise’ equipment, or<br />

methods of work with the lowest noise impacts are selected;<br />

• select the most effective mufflers, enclosures and low-noise tool bits and<br />

blades;<br />

• use alternatives to audible reversing alarms (such as broadband noise<br />

emitting models) that provide a safe system of work, or configure the site<br />

to maximise forward movements of mobile plant;<br />

• use alternatives to diesel/petrol engines and pneumatic units, such as<br />

hydraulic or electric-controlled units, where feasible and reasonable;<br />

• use a temporary noise barrier for small equipment such as hand tools;<br />

• reduce throttle settings and turn off equipment and plant when not used;<br />

• regular inspection and maintenance of all plant and equipment to ensure it<br />

remains in good working order;<br />

• for machines with fitted enclosures, check that doors and door seals are in<br />

good working order and that the doors close properly against the seals;<br />

and<br />

• ensure air lines on pneumatic equipment do not leak and generate noise.<br />