• duration required for construction and maintenance activities in a<br />

Nigerian context.<br />

Based primarily on the operating efficiency of OCGT this technology was<br />

selected for the proposed power plant. The price of the gas feed-stock was<br />

also a determining factor.<br />

3.1.6 Possible Future Conversion of OCGT to CCGT<br />

The OCGT plant has been designed to accommodate the potential conversion<br />

to CCGT with a total net output of approximately 670 MW. The gas turbines<br />

exhausts and stacks have been orientated in such a way as to allow for the<br />

Heat Recovery Steam Generators (HRSGs) to be built directly behind them.<br />

The CCGT will form an extension adjacent to the OCGT facilities with HRSGs<br />

installed next to each gas turbine.<br />

The conversion of the plant to CCGT will require the construction and<br />

installation of four heat recovery steam generators (HRSGs) which will be<br />

connected to the exhaust of each of the existing four gas turbines. It will also<br />

involve the installation of two steam turbine generators. This will create two<br />

CCGT blocks (each a two plus one configuration) such that the gas turbine<br />

and the steam turbine generators are of a similar size, and the transformers are<br />

of a similar size so that they are interchangeable. The principle aim is to<br />

capture excess exhaust heat of the OCGT engine, thus extracting more useful<br />

energy from the fuel and thereby increasing the system's overall efficiency.<br />

The construction of the CCGT plant will take place if and when it is deemed<br />

that the plant conversion from OCGT to CCGT is economically viable.<br />

Consequently, the CCGT plant is excluded from consideration in this EIA.<br />

The environmental and social impacts resulting from the conversion of the<br />

plant to a CCGT system have therefore not been considered within this EIA<br />

and will be identified and assessed within a separate EIA, if required.<br />

3.2 POWER PLANT<br />

3.2.1 Overview of <strong>Power</strong> <strong>Plant</strong> Components<br />

The key Project components are listed in Table 3.1.<br />

Table 3.1<br />

Key Project Components<br />

Key Component<br />

Gas Turbine <strong>Power</strong> House<br />

Additional Information<br />

Four Frame E gas turbines and generators each<br />

with a nominal output of 112.5MW with stack<br />

diverter/ damper units. The gas turbines have<br />

incorporated Dry Low NO x burners.<br />

AZURA EDO IPP<br />

3-3<br />

DRAFT EIA REPORT