Bridgestone Retail Operations, LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

SECTION 07620<br />

SHEET METAL FLASHING AND TRIM<br />

PART 1 GENERAL<br />

1.01 SECTION INCLUDES<br />

A. Flashings, counter flashings, facia, soffit and fabricated sheet metal items, as indicated in<br />

Schedule.<br />

B. Reglets and accessories.<br />

1.02 QUALITY ASSURANCE<br />

A. Perform work in accordance with SMACNA Architectural Sheet Metal Manual requirements and<br />

standard details, except as otherwise indicated.<br />

1.03 SUBMITTALS<br />

A. Sustainable Submittals: No submittals are required. Refer to Section 01352 for Sustainable<br />

recommendations on this project.<br />

PART 2 PRODUCTS<br />

2.01 SHEET MATERIALS<br />

A. Pre-Finished Aluminum: ASTM B 209 (ASTM B 209M); 0.032 inch thick; plain finish shop coated<br />

with fluoropolymer coating, color as indicated on drawings, or equal.<br />

B. Two-Coat Fluoropolymer: AAMA 620. Fluoropolymer finish containing not less than 70% PVDF<br />

resin by weight in color coat.<br />

2.02 ACCESSORIES<br />

A. Fasteners: Galvanized steel, with soft neoprene washers.<br />

B. Primer: Zinc chromate type.<br />

C. Protective Backing Paint: Zinc chromate alkyd.<br />

D. Sealant: Specified in Section 07900.<br />

E. Plastic Cement: ASTM D 4586, Type I.<br />

F. Reglets: Formed to provide secure interlocking of separate reglet and counter-flashing pieces.<br />

1. Material: Aluminum, 0.024 inch (0.61 mm) thick.<br />

G. Scuppers: Plain finish shop pre coated with fluoropolymer coating.<br />

H. Conductor Heads: Plain finish shop pre coated with fluoropolymer coating.<br />

2.03 FABRICATION<br />

A. Form sections true to shape, accurate in size, square, and free from distortion or defects.<br />

B. Form pieces in longest possible lengths.<br />

C. Hem exposed edges on underside 1/2 inch; miter and seam corners.<br />

D. Form material with flat lock seams, except where otherwise indicated. At moving joints, use sealed<br />

lapped, bayonet-type or interlocking hooked seams.<br />

E. Fabricate corners from one piece with minimum 18 inch long legs; seam for rigidity, seal with<br />

sealant.<br />

F. Fabricate vertical faces with bottom edge formed outward 1/4 inch (6 mm) and hemmed to form<br />

drip.<br />

G. Fabricate through-wall flashings in minimum 96 inch long, but not exceeding 12 foot long sections,<br />

under copings, at shelf angles, and where indicated. Fabricate discontinuous lintel, sill and similar<br />

flashings to extend 6 inches beyond each side of wall openings. Return and brake edges.<br />

2.04 MANUFACTURERS<br />

A. Firestone Building Products Co. – Carmel, IN. - No substitutions are permitted<br />

SHEET METAL FLASHING AND TRIM 07620 - Page 1 of 2