Bridgestone Retail Operations, LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

B. Performance Requirements:<br />

1. Structural Members shall be of sufficient size to support design loads as prescribed by<br />

government building codes.<br />

2. Deflection of skylight framing members shall not exceed L/175 when subject to a uniform load<br />

deflection test in accordance with ASTM E330, and per the above specified loads.<br />

3. Water Penetration: No water penetration shall occur when system is tested in accordance<br />

with ASTM E331. Water penetration is defined as the appearance of uncontrolled water<br />

other than condensation on the interior surface of any part of the skylight.<br />

a. Drain to the exterior all water entering at joints or glazing reveals as well as all<br />

condensation occurring within unit construction.<br />

4. Air Infiltration: Air infiltration through the skylight/smoke vent assembly, when tested in<br />

accordance with ASTM E283, shall not exceed 0.06 cubic feet per minute per square foot of<br />

fixed area.<br />

5. Thermal Movement: Skylight/smoke vent assembly shall be so designed and anchored that<br />

there will be no objectionable distortion or stresses in fastening and joinery due to expansion<br />

and contraction when subjected to temperature variance.<br />

6. High Wind Debris Areas: When required by Authorities Having Jurisdiction, skylight/smoke<br />

vent and curb assemblies shall conform with Florida NOA or Dade County product approvals.<br />

7. Snow Loads: Skylight/smoke vents shall be designed to operate in regional snow loads as<br />

noted on structural plans.<br />

1.04 SUBMITTALS<br />

A. Submittal for specified items as required in Section 01300.<br />

1.05 WARRANTY<br />

A. Vendor shall warrant to Firestone that all products comply with this specification. Firestone<br />

reserves the right to refuse and reject material that does not comply with this specification and for<br />

the following reasons based on visual inspections.<br />

B. Vendor agrees to assist in investigation alleged product failures and other user complaints should<br />

they occur. Product failure settlement shall be negotiated between the “Vendor” and “Firestone” at<br />

any time during the duration of the Firestone warranty.<br />

1.06 CHANGES IN PROCESS OR PRODUCT<br />

A. Vendor shall be required to report to Firestone Purchasing Department 30 days prior to producing<br />

and shipping any material when making a change in a purchased raw material, manufacturing<br />

process, manufacturing location, sources, or the product. Firestone will review all changes and<br />

shall reserve the right to require re-qualification of the subject material or equipment. Firestone<br />

reserves the right to approve or reject any proposed changes.<br />