10.03.2015 Views

Specs

Specs

Specs

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Proposed Bridgestone April 20, 2011<br />

NWC of Vance St. & W. Center Ave. PSI Project No. 532281<br />

Lakewood, Colorado Page 2 of 15<br />

any of the noted information is incorrect, please inform us so that we may amend the<br />

recommendations presented in this report, if needed.<br />

3.0 SUBSURFACE INFORMATION<br />

The following sections provide information relating to subsurface conditions in the area<br />

of the proposed addition. The geology section is based upon the, “Geologic Map of the<br />

Greater Denver Area, Front Range Urban Corridor, Colorado” by Donald E. Trimble and<br />

Michael N. Machette, dated 1979 and information relating to subsurface conditions<br />

within the property gathered from our current field study.<br />

3.1 Site Geology and Geologic Hazards<br />

The site is located on the high plains approximately 25 miles east of the foothills of the<br />

Rocky Mountains. Based on the United States Geological Survey (USGS) “Geologic<br />

Map of the Greater Denver Area, Front Range Urban Corridor, Colorado” by Donald E.<br />

Trimble and Michael N. Machette, 1979, the majority of the site is mapped as being<br />

underlain by the Early Tertiary and Late Cretaceous age Denver and Arapahoe<br />

Formations. The Denver and Arapahoe Formations consist of sandstone, mudstone,<br />

claystone and conglomerate and is characterized by andesitic materials.<br />

3. 2 Subsurface Conditions<br />

As part of PSI’s evaluation of this site, PSI drilled 9 exploratory borings, 5 within the building<br />

pad and 4 within the parking lot, at the subject site as indicated on Figure 2, the Boring<br />

Location Map. The borings were drilled to approximate depths of 20 feet below existing<br />

grades within the proposed building area and to approximate depths of 10 feet below the<br />

existing grades in the parking areas. The borings were advanced using a CME-55 truck<br />

mounted drill rig equipped with 4-inch diameter, solid-stem, continuous-flight auger. Soil<br />

samples were recovered at selected depths during drilling with the truck-mounted drill rig<br />

using a Modified California Barrel Sampler (inside diameter- 2.0 inches and outside<br />

diameter- 2.4 inches) driven by a 140-lb. weight free falling 30 inches. The number of<br />

blows required to drive the sampler 12 inches is designated as the penetration resistance<br />

(N-value, blows per foot) and provides an indication of the consistency of cohesive soils<br />

and the relative density of granular materials. While the procedure is similar to that<br />

employed in the Standard Penetration Test (ASTM D1586), the penetration resistance<br />

obtained using the California barrel sampler is generally higher than that obtained using the<br />

standard split spoon sampler.<br />

An engineer from our office observed the drilling of our borings and logs were prepared of<br />

the encountered conditions. Individual logs of the borings are presented on Figures 3<br />

through 11. It should be noted that the subsurface conditions presented on the boring logs<br />

are representative of the conditions at the specific locations drilled. Variations may occur<br />

and should be expected across the site. The stratification represents the approximate<br />

boundary between subsurface materials and the transitions may be gradual and indistinct.<br />

Water level information, if encountered, obtained during our field operations is also shown<br />

on the boring logs.<br />

3.2.1 Subsurface Profile<br />

In general, the overburden soils consisted of light brown to dark brown, moist, very stiff<br />

to stiff sandy clay and clayey sand. The overburden material was found overlying

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!