Bridgestone Retail Operations, LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

If approved by the Zone Construction Manager, the testing engineer shall verify the adequacy of the<br />

welds in question by means of ultrasonic inspection<br />

d. Inspect steel roof deck for compliance with Drawings and Specifications. Report on the<br />

following:<br />

• Select 6 random sheets for each type of deck used and inspect for deck thickness, type and<br />

material.<br />

• Inspect 10 percent of deck welds/connections over the entire roof area for size and spacing<br />

(CWI to perform inspection).<br />

• Inspect 10 percent of side lap connectors over the entire roof area for type, size and<br />

spacing for side al connectors.<br />

END OF SECTION<br />

QUALITY REQUIREMENTS 01400 - Page 11 of 11