Bridgestone Retail Operations, LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

PART 2 PRODUCTS<br />

2.01 MANUFACTURERS<br />

A. Contact documents are based on Firestone Building Products, Michael Orkey at (317)-575-7245.<br />

orkeymichael@firestonebp.com<br />

B. Alternate Manufacturer for Florida NOA and high wind, air borne debris areas:<br />

2.02 MATERIALS<br />

1. Bristolite Skylights, Inc., 800-854-8618.<br />

A. Lens Configuration: SR50, 100% impact modified clear prismatic acrylic, or polycarbonate<br />

prismatic lens over SR25 white prismatic lens. Both layers shall be double glazed and ready for<br />

installation.<br />

1. Outer Lens: SR 50 – 100 percent impact modified clear prismatic acrylic of sufficient<br />

thickness recommended to meet the specified performance requirements. Rated CLASS 1<br />

Hail Resistance (1” hail), CLASS 3 Hail Resistance (1.75” hail).<br />

2. Outer Lens: FBC – HVHZ Approved Polycarbonate.<br />

3. Inner Lens: SR25 White Prismatic Acrylic Lens.<br />

4. High Velocity Hurricane Zone Approved.<br />

B. Glazing Material:<br />

1. Glazing material must have a maximum light distribution characteristic that maximizes the<br />

shading factor. Per Addendum D of ASHRAE 90.1-2007, the diffusing qualities of glazing<br />

must have a minimum haze factor of 90 percent or greater. The combined inner/outer lens<br />

target values shall be as follows:<br />

2. Light Transmittance 67.8 percent minimum. CLASS 1 & CLASS 3 ACRYLIC.<br />

3. Light Transmittance: 60.0 percent minimum. FBC-HVHZ Approved Polycarbonate.<br />

4. Diffusion/Haze Factor: 100 percent min.<br />

5. Solar Heat Gain Coefficient (SHGC): 0.49 maximum. NFRC 200 “U” Value: 0.82 or lower<br />

(glazing and framing) in accordance with NFRC 100 or “unlabeled skylight” default<br />

requirements of ASHRAE 90.1-2007 **NOTE**Select Hail rating. Class 3 units should be<br />

presented as option in high hail risk zones.<br />

a. Hail Resistance Level: Class 1 (1” hail) as tested by certified engineering firm.<br />

b. Hail Resistance Level: Class 3 (1.75” hail) as tested by certified engineering firm.<br />

6. High Velocity Hurricane Zone Approved. Polycarbonate as tested by certified engineering<br />

firm.<br />

C. Frame:<br />

1. ASTM B 221 alloy 6063-T5 extruded aluminum frame with extruded aluminum dome retaining<br />

angle, Insulated thermal break, and integral condensate gutter.<br />

2. Finish: Manufacturer’s standard mill finish.<br />

3. Provide pre-installed 1-1/2” x ¼ inch foam rubber gasket between frame and curb.<br />

4. Provide weather sweep attached to frame.<br />

D. Roof Curb:<br />

1. Color – white.<br />

2. Metal – Galvalume steel construction and liners.<br />

a. Full height mitered and welded corners.<br />

b. Factory installed 3/16” galvanized steel Safe-Security Guard 6” x 6” grid pattern.<br />

c. 1-1/2” thick 3 lb. density fiberglass insulation.<br />

METAL FRAMED SKYLIGHT / SMOKE VENT 08625 - Page 3 of 6