Bridgestone Retail Operations LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

1.07 PROJECT/SITE CONDITIONS<br />

A. Environmental Requirements:<br />

1. Installation shall not begin until building is enclosed, permanent heating and cooling<br />

equipment is in operation and residual moisture from plaster, concrete or terrazzo work has<br />

dissipated.<br />

2. Install panels between 60 degrees F - 75 degrees F (15 - 24 degrees C) and relative humidity<br />

below 65%, ideally at the same conditions as the room’s normal operating temperatures after<br />

building is occupied.<br />

3. Provide ventilation to disperse fumes during application of adhesive as recommended by<br />

adhesive manufacturer.<br />

B. Field Measurements: Verify actual measurements/openings by field measurements before<br />

fabrication; show recorded measurements on shop drawings. Coordinate field measurements and<br />

fabrication schedule with construction progress to avoid construction delays.<br />

C PRECONDITIONING: Prior to installing Varietex, remove the packaging and allow the panels to<br />

acclimate to room temperature and humidity for at least 48 hours. Ideally, the room temperature<br />

and humidity during acclimation and installation should be the same as the final operating<br />

conditions. Panels will provide a clean, aesthetically pleasing finished installation. However, by<br />

nature, fiberglass reinforced plastic paneling may occasionally have small areas that are<br />

aesthetically unacceptable for use. Panels should be inspected on-site prior to installation. If any<br />

portion of material will not provide an acceptable appearance, Kemlite should be notified at once.<br />

Upon verification of unacceptability, that responsibility is for the replacement of defective material<br />

but not for labor or other handling or installation expenses.<br />

1.08 MAINTENANCE<br />

A. Extra Materials: Provide five percent of additional material for use by owner in building<br />

maintenance and repair.<br />

PART 2 PRODUCTS<br />

2.01 DECORATIVE FIBERGLASS REINFORCED PLASTIC (FRP) PANELS<br />

A. Manufacturer: Kemlite Company, Inc.<br />

1. Contact: 23525 W Eames, Channahon, IL 60410; Telephone: (888) DECOFRP, (815) 467-<br />

8600; Fax: (815) 467-8666; E-mail: decofrp@kemlite.com; website:<br />

www.frpdesignsolutions.com.<br />

2. Or equal.<br />

B. Proprietary Products/Systems: FRP panels, including the following:<br />

1. VARIETEX CLASS C (or Class A, if required by Local Authorities)<br />

a. Surface Texture: Sandstone<br />

b. Thickness: 0.09 inch.<br />

c. Weight: 0.73 psf.<br />

d. Size: 4 feet × 8 feet.<br />

e. Color: Refer to drawings.<br />

f. Physical Properties:<br />

1) Flexural Strength (ASTM D790): 14 × 10 3 psi.<br />

2) Flexural Modulus (ASTM D790): 0.4 × 10 6 psi.<br />

3) Tensile Strength (ASTM D638): 7 × 10 3 psi.<br />

4) Tensile Modulus (ASTM D638): 0.8 × 10 6 psi.<br />

SPECIAL WALL SURFACING 09770 Page 3 of 6