Bridgestone Retail Operations, LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

SECTION 16510<br />

INTERIOR LUMINARIES<br />

PART 1 GENERAL<br />

1.01 SECTION INCLUDES<br />

A. Interior luminaries and accessories.<br />

1.02 QUALITY ASSURANCE<br />

Products: Listed and classified by Underwriters Laboratories, Inc. as suitable for the purpose.<br />

PART 2 PRODUCTS<br />

2.01 LUMINAIRES<br />

Furnish products as indicated in drawing fixture schedule.<br />

2.02 LAMPS<br />

Lamp Types: Acceptable Manufacturers: GE, Phillips, Sylvania.<br />

PART 3 EXECUTION<br />

3.01 INSTALLATION<br />

A. Install suspended luminaries and exit signs using pendants supported from swivel hangers.<br />

Provide pendant length required to suspend luminaire at indicated height.<br />

B. Support luminaries larger than 2 x 4 foot size independent of ceiling framing.<br />

C. Locate recessed ceiling luminaries as indicated on reflected ceiling plan.<br />

D. Install surface mounted luminaries and exit signs plumb and adjust to align with building lines and<br />

with each other. Secure to prevent movement.<br />

E. Exposed Grid Ceilings: Support surface mounted luminaries in grid ceiling directly from building<br />

structure.<br />

F. Install recessed luminaries to permit removal from below.<br />

G. Install recessed luminaries using accessories and firestopping materials to meet regulatory<br />

requirements for fire rating.<br />

H. Install clips to secure recessed grid-supported luminaries in place.<br />

I. Install wall mounted luminaries, emergency lighting units, and exit signs at height as indicated on<br />

Drawings.<br />

J. Install specified lamps in each emergency lighting unit, exit sign, and luminaire.<br />

3.02 FIELD QUALITY CONTROL<br />

A. Operate each luminaire after installation and connection. Inspect for proper connection and<br />

operation.<br />

3.03 ADJUSTING<br />

A. Aim and adjust luminaries as indicated.<br />

B. Position exit sign directional arrows as indicated.<br />

3.04 PROTECTION<br />

A. Relamp luminaries that have failed lamps at Substantial Completion.<br />

END OF SECTION<br />

INTERIOR LUMINARIES 16510 - Page 1 of 1