Bridgestone Retail Operations, LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

B. Portland Cement: ASTM C 150, Type I; color as required to produce approved color.<br />

C. Hydrated Lime: ASTM C 207, Type S.<br />

D. Grout Aggregate: ASTM C 404.<br />

E. Water: Clean and potable.<br />

2.03 REINFORCEMENT AND ANCHORAGE<br />

A. Masonry Veneer Anchors: 2-piece anchors that permit differential movement between masonry veneer<br />

and structural backup, hot dip galvanized to ASTM A 153/A 153M, Class B.<br />

1 Wire ties: Manufacturer's standard shape, 0.1875 inch thick.<br />

2 Vertical adjustment: Not less than 3-1/2 inches.<br />

2.04 ACCESSORIES<br />

A. Weeps: Molded PVC grilles, insect resistant.<br />

B. Cavity Mortar Control: Semi-rigid polyethylene or polyester mesh panels, sized to thickness of wall cavity,<br />

and designed to prevent mortar droppings from clogging weeps and cavity vents and allow proper cavity<br />

drainage.<br />

C. Cavity Air Barrier:<br />

1. Liquid applied air and moisture barrier equal to Stoguard by STO Corp on CMU.<br />

2. Sheet applied vapor retarder over stud construction.<br />

3. Elastomeric Thermoplastic Flashing: Composite flashing product consisting of a polyesterreinforced<br />

ethylene interpolymer alloy.<br />

a. Projects: Subject to compliance with requirements, available products that may be<br />

incorporated into the Work include, but are not limited to, the following:<br />

1. DuPont: Thru-Wall Flashing.<br />

2. Hohmann & Barnard, Inc.: Flex-Flash.<br />

3. Hyload, Inc.: Hyload Cloaked Flashing System.<br />

4. Mortar Net USA, Ltd.: Total Flash.<br />

2.05 MORTAR MIXES<br />

A. Mortar for Unit Masonry: ASTM C 270, Proportion Specification.<br />

PART 3 EXECUTION<br />

3.01 COURSING<br />

A. Establish lines, levels, and coursing indicated. Protect from displacement.<br />

B. Maintain masonry courses to uniform dimension. Form vertical and horizontal joints of uniform thickness.<br />

C. Brick Units:<br />

1. Bond: Running.<br />

3.02 PLACING AND BONDING<br />

A. Lay solid masonry units in full bed of mortar, with full head joints, uniformly jointed with other work.<br />

3.03 WEEPS/CAVITY VENTS<br />

A. Install weeps in veneer walls at 24 inches on center horizontally above through-wall flashing, above shelf<br />

angles and lintels, and at bottom of walls.<br />

B. Install cavity mortar diverter at base of cavity as recommended by manufacturer to prevent mortar<br />

droppings from blocking weep/cavity vents.<br />

C. Do not permit mortar to drop or accumulate into cavity air space or to plug weep/cavity vents.<br />