Bridgestone Retail Operations, LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

E. EIFS surfaces in contact with sealants shall be coated with manufacturer approved sealer.<br />

F. EIFS panel tolerance: Maximum variance from plane shall be 1/4” within a 4-foot radius.<br />

3.03 FIELD VISITS / OBSERVATIONS:<br />

A. Observation of the E.I.F.S. installation shall be performed by a representative of the<br />

Manufacturer. A report of each day’s work shall be developed describing the materials and<br />

workmanship to be in compliance with Manufacturers recommendations, or to describe any<br />

deficiencies, with associated correction identified. Reports shall be on E.I.F.S.<br />

manufacturer’s company letterhead. A copy of each report shall be sent to the Owner,<br />

Contractor and Professional of Record. If deficiencies occur, the Contractor shall<br />

immediately perform corrections recommended by E.I.F.S. Manufacturer and insurable by<br />

Property Loss Underwriters.<br />

B. The intent of these specifications are to ensure the system is installed strictly in a manner<br />

that will be warranted by the E.I.F.S. manufacturer and insurable by Property Loss<br />

Underwriters.<br />

END OF SECTION<br />

EIFS 07240 - Page 3 of 3